Read Out Electronics [Home]   [Contact Us]   [Imprint]

Read out electronics VersaSpec 2

The VersaSpec 2 read out electronics is evolved for reading spectral data from several spectral sensors. The powerful 16/32 Bit microcontroller utilizes on board from simple spectra calculations up to real time FFT (download datasheet 2MB)).

Available signal conditioning units for line (area) arrays:
Type Manufacturer Status
S837x Hamamatsu Production
S390x Hamamatsu Production
S9840 Hamamatsu Production
S703x Hamamatsu Development (ask for availability)
S10141x Hamamatsu Development (ask for availability)
S920x Hamamatsu Development (ask for availability)
S997x Hamamatsu Development (ask for availability)
SLUxxx Sensor Unlimited Production
ILX 511 Sony Production
ILX 554 Sony Production
ILX 751 Sony Production
ELIS1024 Panavision Production
LIS1024 Panavision Production
LIF1401 ICHaus Production
LIF1402 ICHaus Production

Specifications
Electrical Parameters
Power supply USB-Hub powered or +6 .. 16V DC
Operation current <100 mA (on USB)
Quiescent current (power down) < 5 mA (interface dependent)
Analog to Digital Conversion Unit
Resolution 16 bit, 2 bit RMS1, 4bit INL, no missing code
Sampling speed 10 MS/sec.
Sampling mode Sample and Hold:1, 4 - fold prog. oversampling
or Correlated Double Sampling
Inputs 2 (odd and even), programmable for positive or negative video signals
Input full scale range 2V or 4V, programmable
Gain 1...5 programmable in 64 steps
Offset External compensation or programmable up to +/-300mV
Interfaces
USB 2.0 Full speed (12 Mbit/sec) (virtual COM Port)
RS232 8,N,1, RxD,TxD, no flow control up to115200 bit/sec.
TTL-UART up to 921600 bit/sec
SPI up to 5 Mbit/sec.
Process control
Trigger input TTL, slope programmable
Shutter output TTL, programmable state and delay
Flash lamp control programmable flash length, programmable burst
Cooling control
TEC 1..3 stages PI-regulated, class D amplifier, low loss power
5V, up to 2 A, 256 bit PWM
Accuracy ± 0.1°C
Temperature Set Range -40 .. +50°C
Firmware
Basic Operations Dark counts, reference counts, transmission, absorbance, (pixelwise or in wavelength steps with pixel wavelength fit up to 4th order), averaging up to 32 times
Extended Operations (optional) Linear and spline interpolation
Fast fourier transformation (frequency analysis),
colour calculation (X;Y;Z, x,y, u’,v’ L*,a,*,b*...)
radiometric calculations (radiance, luminance, CCT,
dominant wavelength, purity, peak wavelength, FWHM...)
Calibration Sets Up to 30, application specific, user accessible

1 without oversampling

© 1998 .. 2009 JETI Technische Instrumente GmbH -- Tatzendpromenade 2 -- D-07745 Jena -- Germany -- January 2009