Optical Parameters
   Spectral range    230 nm - 1000 nm
   Optical resolution (FWHM)    4.5 nm
   Calculated wavelength step    1 nm
   Digital electronic resolution    16 Bit ADC (15 Bit used)
   Viewing angle    1.8° (Luminance mode)
   Measuring distance / diameter    20 cm - Ø 6 mm; 100 cm - Ø 31 mm (luminance mode)
   Measuring values    Spectral radiance    
   Total luminance/ total radiance 
   Total illuminance/ total irradiance 
   Chromaticity coordinates x , y ; u', v'
   Correlated Color Temperature, color purity
   Color Rendering Index, RGB
   Circadian metrics, Photosynthetically Active Radiation
Measuring ranges and accuracie
   Measuring range luminance    0.1 - 7500 cd/m² (higher values with optional filter) @ illuminant A
   Measuring range illuminance    2 - 60 000 lx @ illuminant A
   Luminance accuracy    ± 2 % @ 100 cd/m² and illuminant A
   Luminance reproducibility    ± 1 %@ 100 cd/m² and illuminant A
   Chromaticity accuracy    ± 0.002 x , y @ illuminant A
   Color reproducibility    ± 0.0005 x , y @ illuminant A
   CCT reproducibility    ± 20 K @ illuminant A
   Wavelength accuracy    ± 0.5 nm
Other technical data
   Dispersive element    Imaging grating (flat field)
   Light receiving element    CCD array 2048 pixel
   Power supply    USB powered
   PC interface    USB 2.0 fullspeed
   Dimensions    180 mm * 82 mm * 53 mm
   Weight    450 g
   Operating conditions    Temperature 10 - 40 °C
   Humidity < 85 % relative humidity at 35 °C
Miscellaneous




   All inclusive accessories packet
   Cosine corrector head-piece (for irradiance measurement)  
   Tripod
   Transport box
   PC software JETI LiVal 
   JETI SDK
   Operating instructions and firmware commands (digital)
   USB cable
   Trigger connector
   Calibration    NIST traceable
   Recommended recalibration interval    1 year