Photobiological measurements

complete according to IEC 62471

It is possible to extend specbos 1211UV-2 with specific accessories for photobiological measurements. Such measurements are more and more important especially with regard to the modern bright LED illumination and the related hazard to people, in particular to the eyes and the skin. Typical measuring objects are spot lights in studios and during events, machines with UV illumination and LED modules.

The basic facts of photobiological measurements and the specifics with specbos 1211UV-2 are described in the technical note 26.

All 8 categories of hazardous effects defined in EN 62 471 and ANSI/ IESNA RP-27 can be measured with the system, the only restriction is the measuring range of 230 to 1000 nm.

Measurement of a spot light in a studio
Measurement of a spot light in a studio
Accessories for photobiological measurements
Accessories for photobiological measurements

There are several special accessories are available for this task

  • Optics for 11 mrad and 100 mrad Radiance measurement with UVOD2 filter (ACC 024)
  • Mechanical elements for turning/ tilting (ACC 025)
  • Diffusor for Irradiance measurement (Actinic UV and UVA hazard) (ACC 026)
  • 80° aperture for diffusor (ACC 027)
  • UV filter UG 5 (ACC 021 UG5)

Accessories for the different hazard categories

Hazard category Name of the accessory Part number
Blue light, > 10 000 s Beam shaping optics for 100 mrad Radiance measurement with internal OD2 filter and external filters OD1 + OD2 included in ACC 024
Blue light, > 10 000 s Mechanical elements for turning / tilting to find the maximum emission with ACC 024 ACC 025
Blue light, 10 s to 100 s Beam shaping optics for 11 mrad Radiance measurement with filters OD1 + OD2 included in ACC 024
Blue light, small source Diffusor for Irradiance measurement, measuring area ø 8mm ACC 026
Eye UV-A, Actinic UV, Eye IR, Skin thermal Diffusor for Irradiance measurement - Actinic UV and UV-A hazard, measuring area ø 8mm ACC 026
Eye UV-A, Actinic UV, Eye IR, Skin thermal 80° aperture for diffusor ACC 026 ACC 027
Eye UV-A, Actinic UV, Eye IR, Skin thermal UV filter UG 5 ACC 021 UG5
Retina, thermal (and weak stimulus) Beam shaping optics for 11 mrad Radiance measurement with filters OD1 + OD2 ACC 024/11

Please note:
It is recommended in the standard EN 62471 to proceed photobiological measurements with a double monochromator based system. A spectroradiometer with an array spectrometer as specbos 1211UV-2 can be used only if its applicability is proved! Due to the specifics of photobiological measurements it is recommended to discuss the application with JETI to find the best solution.

specbos 1211UV-2 with Beam shaping optics for 100 mrad Radiance measurement with UVOD1.0 filter (ACC 024/100OD1.0) and mechanical elements for turning / tilting (ACC 025)
specbos 1211UV-2 with Beam shaping optics for 100 mrad Radiance measurement with UVOD1.0 filter (ACC 024/100OD1.0) and mechanical elements for turning / tilting (ACC 025)