spectraval 1511-focus

Stand alone spectroradiometer for add-on optics


spectraval 1511-focus can be used for the measurement of small light emitting objects as LED chips, the segments of alphanumeric displays, back illuminated signs and mini CCFL tubes. In contrast to the standard device spectraval 1511, it has a specifically modified measuring optics and can be used in combination with add-on optics accessories to measure specified measuring diameters in a specified distance. Thanks to its touchpad display the instrument can be used as stand-alone mode.

All optics can be attached easily to the basic instrument by screwing. The used version of the front-end is automatically detected by the instrument and the appropriate calibration data set will be applied.

Highlights

  • Compact solutions
  • Fast measurement
  • Measurement in Radiance (basic configuration) and Irradiance mode (diffusor required)
  • Precise results due to high quality spectrograph and NIST traceable calibration
  • Comfortable handling due to Bluetooth connection
  • Radiometric software JETI LiVal is included in the standard scope of delivery

 

Spectroradiometer JETI spectraval 1511-focus
Spectroradiometer JETI spectraval 1511-focus
Optical parameters
  • Spectral range:         380 … 780 nm
  • Optical bandwidth:   4.5 nm
  • Measuring range:    
    • Luminance 0.2 … 180 000 cd/m² (Illuminant A)
    • Luminance 0.2 … 140 000 cd/m2 (typical warm white LED)
      (higher values with optional filter)
Measuring quantities
  • Luminance, Radiance
  • xy and u' v' coordinates
  • Dominant wavelength, Color purity
  • Correlated Color Temperature (CCT)
  • CRI, CQS, TM-30
  • Circadian metrics, PAR

All accessories of spectraval 1511-focus are coded. The software switches to the related measuring mode and the appropriate calibration data will be used when an accessory was attached to the device.

Add-on optics for different measuring geometries
JETI offers a variety of add-on optics to achive certain different measuring geometries.

Standard diffusor
spectraval 1511-focus measures in spectral Radiance mode. It is possible to convert it into a spectral Irradiance meter by attaching a diffusor.

In axis remote diffusor
If the measurement needs to be done in locations with limited space conditions then the remote diffusor can be used. It is a diffusor which is coupled to the spectraval device by an optical fiber bundle. The measurement is done in axis to the fiber bundle. Different fiber lengths are available.

90° remote diffusor
If the measurement needs to be done under limited space conditions and the in axis fiber coupled diffusor is not suited, then the 90° fiber coupled diffusor can be applied. Different fiber lengths are available.

Dolby/realD filter cap pairs
The calibration of 3D projectors needs to be done through the right and left eye glasses. spectraval 1511-focus can be equipped with caps containing the filters of Dolby and realD projection. The usage of these filter pairs allows a precise measurement of 3D projections.

Neutral density filter
spectraval 1511-focus can measure up to 100 000 cd/m² (typical white LED spectrum). An additional neutral density filter allows to shift the measuring range towards higher Luminance levels.

Add-on optics for different measuring geometries
JETI offers a variety of add-on optics to achive certain different measuring geometries. There are different imaging optics: optics for specified distance ratios, optics for specified measuring angles (for any measuring distance) and customized optics.

Battery charger

Bluetooth USB adapter

Carrying case/ bag

Protective cap

Straylight protection tube
The straylight protection tube prevents the influence of surrounding light on Radiance measurements. It is mainly used for display measurements.

Tripod

Display and projection measurement
 
Documents
Datasheets
iconPDFspectraval 1511 (510.91 KB) 
Drawings
Documentation
Software
Software JETI LiVal
  • Demo version
    Recommended for download if you want to familiarise yourself with the software. Demo version simulates measurements without a connected JETI.
    iconZIPJETI LiVal Demo (6.07 MB)UPDATED 
  • Full version
    Recommended for download if you want to test a newer version of JETI LiVal with your device. Full version does not simulate measurements without a connected device.
    iconZIPJETI LiVal Version 8.0.8 (6.07 MB)UPDATED 
JETI SDK
JETI SDK
iconZIPJETI SDK Version 4.8.10 (5.97 MB)UPDATED 
iconPDFJETI SDK Changelog (156.75 KB) 
Firmware
We use cookies
Essential Cookies

The essential cookies are always active. The website will not work without this. The essential cookies comply with all guidelines for the protection of your personal data.

Optional Cookies

However, some applications can only be guaranteed with the help of cookies, which could also forward your data to unsafe third countries. Their privacy policy applies to these applications:

  • YouTube (Videos)
  • Google Analytics

You can find out more about what cookies are and how they work in the privacy policy.

Do you agree to the use of all cookies?