It is possible to add the measurement mode Irradiance by attaching an optional diffusor.
Various add-on optics are available to change the imaging conditions during Radiance measurement (only available for specbos 1211-focus-2).
On special request specbos 1211-2 can be calibrated with a diffusor in Radiant Intensity mode.
Additionally it is possible to combine specbos 1211-2 with an integrating sphere for Radiant flux measurements.
| Description | Applications | Interfaces | |
| specbos 1211-UV-2 | Extended wavelenght range from 230 nm to 1000 nm |
|
USB2.0 |
| specbos 1211-focus-2 | Compatible with add-on optics | USB2.0 | |
| specbos 1211-LAN-2 | Additional LAN interface, e.g. for production environment | LAN and USB2.0 (power supply neccessary) | |
| specbos 1211-BT-2 | More flexibility with additional Bluetooth interface | Bluetooth and USB2.0 | |
| specbos 1211-RS-2 | Additional serial interface | RS232 and USB2.0 (power supply necessary for RS232 operation) |
| specbos 1211-UV-2 | Description Extended wavelenght range from 230 nm to 1000 nm |
Applications
|
Interfaces USB2.0 |
specbos 1211-focus-2 |
Desccription Compatible with add-on optics |
Applications |
Interfaces USB2.0 |
specbos 1211-LAN-2 |
Desccription Additional LAN interface, e.g. for production environment |
Applications |
Interfaces LAN and USB2.0 (power supply neccessary) |
specbos 1211-BT-2 |
Description More flexibility with additional Bluetooth interface |
Applications |
Interfaces: Bluetooth and USB2.0 |
specbos 1211-RS-2 |
Description Additional serial interface |
Applications |
Interfaces: RS232 and USB2.0 (power supply necessary for RS232 operation) |
Optical parameters
Dimensions |
Measuring quantities
|
specbos 1211-2 can detect up to four accessories automatically, the software switches to the related measuring mode and uses the appropriate calibration data. More accessories have to be selected manually in the software.
Add-on optics for different measuring geometries
JETI offers a variety of add-on optics to achive certain different measuring geometries.
Standard diffusor
The pure specbos 1211-2 measures in spectral Radiance mode. It is possible to convert it into a spectral Irradiance meter by attaching a diffusor.
90° diffusor
The standard diffusor of the device acts in line to the device. If the Illuminance at a low height above a surface needs to be measured, then the 90° diffusor can be applied. It is also available with attenuation filters to extend the Illuminance measuring range.
In axis remote diffusor
If the measurement needs to be done in locations with limited space conditions then the remote diffusor can be used. It is a diffusor which is coupled to the spectraval device by an optical fiber bundle. The measurement is done in axis to the fiber bundle. Different fiber lengths are available.
90° remote diffusor
If the measurement needs to be done under limited space conditions and the in axis fiber coupled diffusor is not suited, then the 90° fiber coupled diffusor can be applied. Different fiber lengths are available.
Diffusors with attenuation filter
specbos 1211-2 with its standard diffusor can measure up to about 1.500.000 lx (typical white LED spectrum). If it is necessary to measure higher Illuminances, then a special diffusor with additional attenuation filter can be used.
Dome
The dome is equipped with a glass dom and it is IP67 tested. It can be mounted on roofs or outside walls and allows a detection of the optical sky radiation.
Fast diffusors
If low Illuminance levels must be measured, then the measuring time will be long when using the standard diffusor of the device. It is possible to use “fast” diffusors, but only if the cosine matching of the diffusor is not of primary importance, e.g. in case of point like sources.
Dolby/realD filter cap pairs
The calibration of 3D projectors needs to be done through the right and left eye glasses. specbos 1211-2 can be equipped with caps containing the filters of Dolby and realD projection. The usage of these filter pairs allows a precise measurement of these 3D projection system.
Neutral density filter
specbos 1211-2 can measure up to 100 000 cd/m². An additional neutral density filter allows to shift the measuring range towards higher Luminance levels.
VIS filter
specbos 1211-2 can be equipped with a VIS filter to reduce its wavelength range to 350 … 780 nm. This is especially interesting for measurements with a low VIS intensity but much signal in IR or UV.
Integrating spheres
To extend the functionality of JETI specbos 1211-2 to Radiant flux measurements, JETI offers three different models of integrating spheres.
Straylight protection tube
The straylight protection tube prevents the influence of surrounding light on Radiance measurements. It is mainly used for display measurements. The fixed length of the tube is 16 cm.
Stray light correction matrix
In order to reduce stray light in array spectroradiometers while taking advantage of their portability, JETI offers a stray light correction matrix.
Light effects
|
Lamps
|
LED measurement
|
Display and projection measurement |
General applications |
Miscellaneous
|
External softwareJETI does not guarantee the function of JETI products with external software. JETI is not liable for any changes of external software. Please contact the supplier of the external software in case of any problem.External software packages
Hardware related software
|
AGD Systems , a UK based company, makes easy-to-integrate, globally compatible ITS (intelligent traffic systems) product solutions designed to help create safer, greener, more efficient traffic and transport environments. Now they decide to use a JETI specbos 1211-2. We have shipped the device today.
ML Optic's solutions are used worldwide by customers in the life sciences, aerospace and emerging markets. We are pleased to be a part of these solutions and have shipped the specbos 1211-2 to Thailand today.
We are very happy to announce that we have shipped a specbos 1211-2 to the renowned Oregon State University today. We think research, teaching & JETI is a very good combination.
Google Germany GmbH is buying a JETI specbos 1211-2. Good choice! We have shipped the device today.