Spectroradiometer JETI specbos 2501-UV

Please add one or more of the following add-ons to configure specbos 2501 according to your requirements:
Optical parameters
Dimensions
|
Measuring quantities
|
JETI specbos 2501-UV can detect up to four accessories automatically, the software switches to the related measuring mode and uses the appropriate calibration data. More accessories have to be selected manually in the software.
Accessories for photobiological measurements complete according to IEC 62471
These accessories can be used to measure all 8 categories of hazardous effects defined in EN 62 471 and ANSI/ IESNA RP-27.
Add-on optics for different measuring geometries
JETI offers a variety of add-on optics to achive certain different measuring geometries. There are different imaging optics: optics for specified distance ratios, optics for specified measuring angles (for any measuring distance) and customized optics.
Add-on optics for measurement of VR/AR glasses
JETI offers add-on optics to perform measurements of VR/AR glasses. These optics are only available for JETI specbos 2501 (equipped with focus add-on).
Standard diffusor
JETI specbos 2501-UV measures in spectral Radiance mode. It is possible to convert it into a spectral Irradiance meter by attaching a diffusor.
90° diffusor
The standard diffusor of the device acts in line to the device. If the Illuminance at a low height above a surface needs to be measured, then the 90° diffusor can be applied. It is also available with attenuation filters to extend the Illuminance measuring range.
In axis remote diffusor
If the measurement needs to be done in locations with limited space conditions then the remote diffusor can be used. It is a diffusor which is coupled to the spectraval device by an optical fiber bundle. The measurement is done in axis to the fiber bundle. Different fiber lengths are available.
90° remote diffusor
If the measurement needs to be done under limited space conditions and the in axis fiber coupled diffusor is not suited, then the 90° fiber coupled diffusor can be applied. Different fiber lengths are available.
Diffusors with attenuation filter
JETI specbos 2501-UV with its standard diffusor can measure up to about 1.500.000 lx (typical white LED spectrum). If it is necessary to measure higher Illuminances, then a special diffusor with additional attenuation filter can be used.
Dome
The dome is equipped with a glass dom and it is IP67 tested. It can be mounted on roofs or outside walls and allows a detection of the optical sky radiation.
Dolby/realD filter cap pairs
The calibration of 3D projectors needs to be done through the right and left eye glasses. specbos 2501-UV can be equipped with caps containing the filters of Dolby and realD projection. The usage of these filter pairs allows a precise measurement of these 3D projection system.
Neutral density filters
An additional neutral density filter allows to shift the measuring range towards higher Luminance levels.
VIS filter
JETI specbos 2501-UV can be equipped with a VIS filter to reduce its wavelength range to 350 … 780 nm. This is especially interesting for measurements with a low VIS intensity but much signal in IR or UV.
Integrating spheres
To extend the functionality of JETI specbos 2501-UV to radiation flux measurements, JETI offers three different models of integrating spheres.
Straylight protection tube
The straylight protection tube prevents the influence of surrounding light on Radiance measurements. It is mainly used for display measurements. The fixed length of the tube is 16 cm.
Stray light correction matrix
In order to reduce stray light in array spectroradiometers while taking advantage of their portability, JETI offers a stray light correction matrix.
Light effects
|
Lamps |
Miscellaneous
|
External softwareJETI does not guarantee the function of JETI products with external software. JETI is not liable for any changes of external software. Please contact the supplier of the external software in case of any problem.External software packages
Hardware related software
|