Accessories for hazard measurement
Photobiological measurements complete according to IEC 62471
Article number: ACC 024, ACC 025, ACC 026, ACC 027, ACC 054, ACC 080, ACC 081Device: specbos 2501-UV, specbos 1211-UV-2
JETI UV spectroradiometer specbos can be equipped with accessories for measurements of all photobiological measurements in the wavelength range from 200 to 1100 nm (specbos 2501-UV) or 230 to 1000 nm (specbos 1211-UV-2), defined by EN 62471. These accessories have been completely developed according to IEC 62471. All 8 categories of hazardous effects defined in EN 62 471 and ANSI/ IESNA RP-27 can be measured with the system, the only restriction is the measuring range of 200 to 1100 nm.
More basic facts of photobiological measurements and the specifics with specbos 2501-UV are described in the technical note 26.
| Measuring mode | Hazard category | Accessory name | Part number |
| Radiance | Blue Light Hazard | Beam shaping optics for 100 mrad and for 11 mrad with internal attenuation and additional external UVOD1.0 and UVOD2.0 filters | ACC 024 (specbos 1211-UV-2) ACC 080 (specbos 2501-UV) |
| Radiance | Blue Light Hazard | Beam shaping optics for 100 mrad with internal attenuation and additional external UVOD1.0 and UVOD2.0 filters | ACC 024/100 (specbos 1211-UV-2) ACC 080/100 (specbos 2501-UV) |
| Radiance | Blue Light Hazard | Aperture tube for 1.7 mrad, measurements only in combination with ACC 026 or ACC 081 and in a fixed distance of 200 mm |
ACC 054 (specbos 1211-UV-2 & specbos 2501-UV) |
| Radiance | Retina thermal | Beam shaping optics for 11 mrad with internal OD2 filter and additional external OD1 and OD2 filters | Included in ACC 024 or separately as ACC 024/11 (specbos 1211-UV-2) Included ACC 080 or separately as ACC 080/11 (specbos 2501-UV) |
| Radiance | Blue Light Hazard, Retina thermal | Mechanical elements for turning/ tilting the device to find the maximum emission of the source | ACC 025 (specbos 1211-UV-2 & specbos 2501-UV) |
| Irradiance | Eye UVA, Actinic UV, Eye IR, Skin thermal, Blue light small source | Diffusor for Irradiance measurement, spot size Ø8 mm | ACC 026 (specbos 1211-UV-2) ACC 081 (specbos 2501-UV) |
| Irradiance | Eye UVA, Actinic UV, Eye IR, Skin thermal | 80° aperture for Diffusor ACC 026 or ACC 081 | ACC 027 (specbos 1211-UV-2 specbos 2501-UV) |
| Measuring mode: Radiance | Hazard category: Blue Light Hazard |
Accessory name: Beam shaping optics for 100 mrad and for 11 mrad with internal attenuation and additional external UVOD1.0 and UVOD2.0 filters |
Part number: ACC 024 (specbos 1211-UV-2) ACC 080 (specbos 2501-UV) |
| Measuring mode: Radiance | Hazard category: Blue Light Hazard |
Accessory name: Beam shaping optics for 100 mrad with internal attenuation and additional external UVOD1.0 and UVOD2.0 filters |
Part number: ACC 024/100 (specbos 1211-UV-2) ACC 080/100 (specbos 2501-UV) |
| Measuring mode: Radiance | Hazard category: Blue Light Hazard |
Accessory name: Aperture tube for 1.7 mrad, measurements only in combination with ACC 026 or ACC 081 and in a fixed distance of 200 mm |
Part number: ACC 054 (specbos 1211-UV-2 & specbos 2501-UV) |
| Measuring mode: Radiance | Hazard category: Retina thermal |
Accessory name: Beam shaping optics for 11 mrad with internal OD2 filter and additional external OD1 and OD2 filters |
Part number: Included in ACC 024 or separately as ACC 024/11 (specbos 1211-UV-2) Included ACC 080 or separately as ACC 080/11 (specbos 2501-UV) |
| Measuring mode: Radiance | Hazard category: Blue Light Hazard, Retina thermal |
Accessory name: Mechanical elements for turning/ tilting the device to find the maximum emission of the source |
Part number: ACC 025 (specbos 1211-UV-2 & specbos 2501-UV) |
| Measuring mode: Irradiance | Hazard category: Eye UVA, Actinic UV, Eye IR, Skin thermal, Blue light small source |
Accessory name: Diffusor for Irradiance measurement, spot size Ø8 mm |
Part number: ACC 026 (specbos 1211-UV-2) ACC 081 (specbos 2501-UV) |
| Measuring mode: Irradiance | Hazard category: Eye UVA, Actinic UV, Eye IR, Skin thermal |
Accessory name: 80° aperture for Diffusor ACC 026 or ACC 081 |
Part number: ACC 027 (specbos 1211-UV-2 specbos 2501-UV) |
JETI also offers
| Accessory name | Part number |
| Additional filter cap for ACC 024, OD or bandpasstype | ACC 029UVODX.X (specbos 1211-UV-2 specbos 2501-UV) |
| Adapter UG11 | ACC 021 UG11 (specbos 1211-UV-2) ACC 082 UG11 (specbos 2501-UV) |
| Accessory name: Additional filter cap for ACC 024, OD or bandpasstype | Part number: ACC 029UVODX.X (specbos 1211-UV-2 & specbos 2501-UV) |
| Accessory name: Adapter UG11 | Part number: ACC 021 UG11 (specbos 1211-UV-2) ACC 082 UG11 (specbos 2501-UV) |
Please note:
It is recommended in the standard EN 62471 to proceed photobiological measurements with a double monochromator based system. A spectroradiometer with an array spectrometer such as specbos 2501-UV can be used only if its applicability is proved! Due to the specifics of photobiological measurements it is recommended to discuss the application with JETI to find the best solution.
Photobiological measurements complete according to IEC 62471.pdf