Accessories for hazard measurement
Photobiological measurements complete according to IEC 62471
Article number: ACC 024, ACC 025, ACC 026, ACC 027, ACC 054, ACC 080, ACC 081Device: specbos 2511-UV, specbos 2501-UV, specbos 1211-UV-2
JETI UV spectroradiometer specbos can be equipped with accessories for measurements of all photobiological measurements in the wavelength range from 200 to 1100 nm (specbos 2511-UV, specbos 2501-UV) or 230 to 1000 nm (specbos 1211-UV-2), defined by EN 62471. These accessories have been completely developed according to IEC 62471. All 8 categories of hazardous effects defined in EN 62 471 and ANSI/ IESNA RP-27 can be measured with the system, the only restriction is the measuring range of 200 to 1100 nm.
More basic facts of photobiological measurements and the specifics with specbos 2501-UV are described in the technical note 26.

| Measuring mode | Hazard category | Accessory name | Part number |
| Radiance | Blue Light Hazard | Beam shaping optics for 100 mrad and for 11 mrad with internal attenuation and additional external UVOD1.0 and UVOD2.0 filters | ACC 024 (specbos 1211-UV-2) ACC 080 (specbos 2511-UV / 2501-UV) |
| Radiance | Blue Light Hazard | Beam shaping optics for 100 mrad with internal attenuation and additional external UVOD1.0 and UVOD2.0 filters | ACC 024/100 (specbos 1211-UV-2) ACC 080/100 (specbos 2511-UV / specbos 2501-UV) |
| Radiance | Blue Light Hazard | Aperture tube for 1.7 mrad, measurements only in combination with ACC 026 or ACC 081 and in a fixed distance of 200 mm |
ACC 054 (specbos 1211-UV-2 & specbos 2511-UV / specbos 2501-UV) |
| Radiance | Retina thermal | Beam shaping optics for 11 mrad with internal OD2 filter and additional external OD1 and OD2 filters | Included in ACC 024 or separately as ACC 024/11 (specbos 1211-UV-2) Included ACC 080 or separately as ACC 080/11 (specbos 2511-UV / specbos 2501-UV) |
| Radiance | Blue Light Hazard, Retina thermal | Mechanical elements for turning/ tilting the device to find the maximum emission of the source | ACC 025 (specbos 1211-UV-2 & specbos 2511-UV / specbos 2501-UV) |
| Irradiance | Eye UVA, Actinic UV, Eye IR, Skin thermal, Blue light small source | Diffusor for Irradiance measurement, spot size Ø8 mm | ACC 026 (specbos 1211-UV-2) ACC 081 (specbos 2511-UV / specbos 2501-UV) |
| Irradiance | Eye UVA, Actinic UV, Eye IR, Skin thermal | 80° aperture for Diffusor ACC 026 or ACC 081 | ACC 027 (specbos 1211-UV-2 & specbos 2511-UV / specbos 2501-UV) |
| Measuring mode: Radiance | Hazard category: Blue Light Hazard |
Accessory name: Beam shaping optics for 100 mrad and for 11 mrad with internal attenuation and additional external UVOD1.0 and UVOD2.0 filters |
Part number: ACC 024 (specbos 1211-UV-2) ACC 080 (specbos 2511-UV / 2501-UV) |
| Measuring mode: Radiance | Hazard category: Blue Light Hazard |
Accessory name: Beam shaping optics for 100 mrad with internal attenuation and additional external UVOD1.0 and UVOD2.0 filters |
Part number: ACC 024/100 (specbos 1211-UV-2) ACC 080/100 (specbos 2511-UV / 2501-UV) |
| Measuring mode: Radiance | Hazard category: Blue Light Hazard |
Accessory name: Aperture tube for 1.7 mrad, measurements only in combination with ACC 026 or ACC 081 and in a fixed distance of 200 mm |
Part number: ACC 054 (specbos 1211-UV-2 & specbos 2511-UV / 2501-UV) |
| Measuring mode: Radiance | Hazard category: Retina thermal |
Accessory name: Beam shaping optics for 11 mrad with internal OD2 filter and additional external OD1 and OD2 filters |
Part number: Included in ACC 024 or separately as ACC 024/11 (specbos 1211-UV-2) Included ACC 080 or separately as ACC 080/11 (specbos 2511-UV / 2501-UV) |
| Measuring mode: Radiance | Hazard category: Blue Light Hazard, Retina thermal |
Accessory name: Mechanical elements for turning/ tilting the device to find the maximum emission of the source |
Part number: ACC 025 (specbos 1211-UV-2 & specbos 2511-UV / 2501-UV) |
| Measuring mode: Irradiance | Hazard category: Eye UVA, Actinic UV, Eye IR, Skin thermal, Blue light small source |
Accessory name: Diffusor for Irradiance measurement, spot size Ø8 mm |
Part number: ACC 026 (specbos 1211-UV-2) ACC 081 (specbos 2511-UV / 2501-UV) |
| Measuring mode: Irradiance | Hazard category: Eye UVA, Actinic UV, Eye IR, Skin thermal |
Accessory name: 80° aperture for Diffusor ACC 026 or ACC 081 |
Part number: ACC 027 (specbos 1211-UV-2 specbos 2511-UV / 2501-UV) |
JETI also offers
| Accessory name | Part number |
| Additional filter cap for ACC 024, OD or bandpasstype | ACC 029UVODX.X (specbos 1211-UV-2 & 2511-UV / specbos 2501-UV) |
| Adapter UG11 | ACC 021 UG11 (specbos 1211-UV-2) ACC 082 UG11 (specbos 2511-UV / 2501-UV) |
| Accessory name: Additional filter cap for ACC 024, OD or bandpasstype | Part number: ACC 029UVODX.X (specbos 1211-UV-2 & 2511-UV / specbos 2501-UV) |
| Accessory name: Adapter UG11 | Part number: ACC 021 UG11 (specbos 1211-UV-2) ACC 082 UG11 (specbos 2511-UV / 2501-UV) |
Please note:
It is recommended in the standard EN 62471 to proceed photobiological measurements with a double monochromator based system. A spectroradiometer with an array spectrometer such as specbos 2501-UV can be used only if its applicability is proved! Due to the specifics of photobiological measurements it is recommended to discuss the application with JETI to find the best solution.